Smart Storage Administrator CLI (HPESSACLI)
|
|
Version 2.60-19.0
|
|
10/13/2016
|
|
|
|
Description
|
|
-----------
|
|
Smart Storage Administrator CLI is the command line-based disk configuration
|
|
program for Smart RAID/HBA controllers.
|
|
|
|
* All other product names mentioned herein may be trademarks of their
|
|
respective companies.
|
|
|
|
Supported Operating Systems and Platforms
|
|
-----------------------------------------
|
|
Linux 32-bit components:
|
|
SuSE Linux Enterprise Server 10
|
|
SuSE Linux Enterprise Server 11
|
|
Red Hat Enterprise Linux 5
|
|
Red Hat Enterprise Linux 6
|
|
Red Hat Enterprise Linux 7
|
|
|
|
Linux 64-bit components:
|
|
SuSE Linux Enterprise Server 10 (x86_64)
|
|
SuSE Linux Enterprise Server 11 (x86_64)
|
|
Red Hat Enterprise Linux 5 (x86_64)
|
|
Red Hat Enterprise Linux 6 (x86_64)
|
|
Red Hat Enterprise Linux 7 (x86_64)
|
|
Debian Sarge 64 bit
|
|
Debian Etch (amd64)
|
|
|
|
NOTE: For Red Hat Enterprise Linux 7.1 the sg driver must be manually
|
|
added so that it is loaded at boot time. Without the sg driver being
|
|
loaded, devices or controllers may not be discovered.
|
|
Here is a recommended way to do this:
|
|
|
|
sudo echo sg > /etc/modules-load.d/sg.conf
|
|
sudo rebo
|
|
|
|
* Any platform that requires the CCISS driver should use version 3.6.28 or newer.
|
|
|
|
These drivers are available from http://support.hpe.com.
|
|
|
|
Supported Controllers
|
|
---------------------
|
|
Dynamic Smart Array B110i SATA RAID
|
|
Smart Array P212 Controller
|
|
Smart Array P410 Controller
|
|
Smart Array P410i Controller
|
|
Smart Array P411 Controller
|
|
Smart Array P711m Controller
|
|
Smart Array P712m Controller
|
|
Smart Array P812 Controller
|
|
|
|
Dynamic Smart Array B120i
|
|
Dynamic Smart Array B320i
|
|
Smart Array P220i Controller
|
|
Smart Array P222 Controller
|
|
Smart Array P420 Controller
|
|
Smart Array P420i Controller
|
|
Smart Array P421 Controller
|
|
Smart Array P721m Controller
|
|
Smart Array P822 Controller
|
|
|
|
Smart Array P230i Controller
|
|
Smart Array P430 Controller
|
|
Smart Array P431 Controller
|
|
Smart Array P530 Controller
|
|
Smart Array P531 Controller
|
|
Smart Array P731m Controller
|
|
Smart Array P830 Controller
|
|
Smart Array P830i Controller
|
|
|
|
Dynamic Smart Array B140i
|
|
Smart HBA H240 Controller
|
|
Smart HBA H240ar Controller
|
|
Smart HBA H240nr Controller
|
|
Smart HBA H241 Controller
|
|
Smart HBA H244br Controller
|
|
Smart Array P240nr Controller
|
|
Smart Array P244br Controller
|
|
Smart Array P246br Controller
|
|
Smart Array P440 Controller
|
|
Smart Array P440ar Controller
|
|
Smart Array P441 Controller
|
|
Smart Array P542D Controller
|
|
Smart Array P741m Controller
|
|
Smart Array P840 Controller
|
|
Smart Array P840ar Controller
|
|
Smart Array P841 Controller
|
|
|
|
Installing and running Smart Storage Administrator
|
|
--------------------------------------------------------------
|
|
Installation:
|
|
SSACLI is distributed using Red Hat Package Manager (RPM) packages and
|
|
.deb packages for Debian.
|
|
If there is an older version of SSACLI installed on the system, please
|
|
use "rpm -e ssacli" to remove it first. Use "rpm -i <file name>" to
|
|
install the application.
|
|
Please type "man rpm" for other details regarding RPM.
|
|
NOTE: On Debian systems, a ".deb" package file can be installed using the
|
|
"dpkg -i ssacli.xxx.deb" command. The dpkg -r ssacli command is used to
|
|
remove the package.
|
|
The software resides in /opt/smartstorageadmin/ssacli and the executable
|
|
name is ssacli which is located in /usr/sbin.
|
|
|
|
When attempting to run SSACLI on any HPE-supported version of Linux, it is
|
|
highly recommended that you install the latest version of the HPE ProLiant
|
|
Smart RAID/HBA controller driver for your intended Linux operating system.
|
|
Drivers may be obtained by clicking on "HPE Servers, Storage and Networking"
|
|
from HPE's support website at: http://support.hpe.com
|
|
|
|
For Debian 64 bit:
|
|
dpkg -i --force-architecture <file name>. ssacli requires the libunwind
|
|
bit package to be installed.
|
|
|
|
Running SSACLI:
|
|
|
|
Make sure that you have gone through the following checklist:
|
|
. You run ssacli as root.
|
|
|
|
To start the application:
|
|
If /usr/sbin is already added in your path, just type:
|
|
"ssacli".
|
|
More options can be found by typing "ssacli help".
|
|
|
|
Exiting SSACLI:
|
|
1. To exit the SSACLI, type "exit" while at the CLI command console.
|
|
|
|
Additional Notes
|
|
----------------
|
|
1. After creating or deleting logical drives with SSACLI, under some special
|
|
circumstances, the device name mapping might change after you first reboot
|
|
the system. Also, Linux might see previously not visible logical drives
|
|
after rebooting. This name mapping problem is common to all SCSI devices
|
|
on Linux.
|
|
2. Do not insert or remove a controller driver module when ssascli is
|
|
running.
|
|
3. Please stop the HPE Storage Agents when deleting logical drives
|
|
since HPE Storage Agents keeps all logical drives open.
|
|
4. If all physical drives on a controller fail or are removed, software keys
|
|
will not be saved to the controller.
|
|
5. SSACLI may appear unresponsive during heavy array controller I/O
|
|
conditions, such as during a partition format or a logical drive rebuild.
|
|
6. When using Linux as the host operating system, if a Smart Array controller
|
|
has 16 or more volumes configured, deleting any volume in SSACLI will not
|
|
update the /proc/partitions to reflect the deletion of the device node
|
|
associated with that volume. Rebooting the server will cause the update to
|
|
happen. Note that there is also a limitation that only the first 16
|
|
volumes configured will be available to the operating system.
|
|
7. On RHEL5 systems, for this version of the SSACLI version 3.6.18-10 or
|
|
newer of the HPE ProLiant Smart RAID/HBA controller driver for Red Hat
|
|
Enterprise Linux 5 (x86, x86-64) is required. Drivers may be obtained by
|
|
clicking on "HPE Servers, Storage and Networking" from HPE's support
|
|
website at: http://support.hpe.com
|
|
|
|
Notes for SSA Scripting
|
|
-----------------------
|
|
* SSA scripting (SSASCRIPTING) now uses a new engine to auto configure volumes.
|
|
When using the AUTO mode, it will attempt to configure two volumes; an OS
|
|
volume and a Data volume. The OS volume will be RAID1, while the Data volume
|
|
will be the highest possible RAID up to 6, depending on the number of disks
|
|
and RAID modes supported by the controller. Spares may be automatically
|
|
allocated. All user input in the input config file is ignored in AUTO mode.
|
|
The actual volumes created will depend on the controller, the number and size
|
|
of disks and the status of license keys in the controller.
|
|
* In scripting input/output, 2 disk mirrors are considered RAID1, 4 disk and
|
|
higher mirrors are RAID10. For compatibility, input scripts still accept
|
|
RAID1 for 4+ disk mirrors, however we recommend moving to the new argument
|
|
terminology as soon as possible.
|
|
* ARRAY and VOLUME arguments in configure mode can be specified as "Next",
|
|
which will use the next available ID.
|
|
* DRIVE arguments can be a number or wildcard, e.g. "*" or "2". In the first
|
|
example, all available drives will be used, in the second two drives will be
|
|
used.
|
|
* The CONTROLLER argument can be FIRST. Controllers are sorted after discovery,
|
|
the order being: internal before external, in ascending slot order. This
|
|
ensures that the input CONTROLLER=FIRST will target an internal controller
|
|
(SLOT=0) or the controller in the lowest PCI slot.
|
|
* To improve performance, use the REPEAT keyword when creating multiple
|
|
identical logical drives.
|
|
|
|
Support
|
|
-------
|
|
For support for SSACLI and Smart RAID/HBA controllers, please visit
|
|
http://support.hpe.com.
|