Imported Upstream version 3.30.14.0

This commit is contained in:
Mario Fetka 2018-11-28 15:44:14 +01:00
parent 2503a935dd
commit 9a8e1f9f6d
5 changed files with 28 additions and 23 deletions

View File

@ -1,6 +1,6 @@
Smart Storage Administrator Diagnostics and SmartSSD Wear Gauge Utility CLI
Version 3.10-3.0
5/17/2017
Version 3.30-14.0
4/24/2018
Description
-----------

Binary file not shown.

View File

@ -3,9 +3,9 @@
<meta lang="en">
<product id="76473ecbae4849129ae6336d910a3b6f">
<product_version>
<id product="76473ecbae4849129ae6336d910a3b6f" version="7ac35b5426bd47d8ac275c0579a6052a" lucid_version="hpessaducli.linux.x64@3.10-3.0__pubsw-linux_de,en,es,fr,it,ja"/>
<id product="76473ecbae4849129ae6336d910a3b6f" version="295e6e1647294f9fbe512a2980ee41f2" lucid_version="hpessaducli.linux.x64@3.30.14.0__pubsw-linux_de,en,es,fr,it,ja"/>
<different>new</different>
<build number="13"/>
<build number="7"/>
<type id="publishablesoftware-linux"/>
<name>
<name_xlate lang="en">HPE Smart Storage Administrator Diagnostic Utility (HPE SSADU) CLI for Linux 64-bit</name_xlate>
@ -13,7 +13,7 @@
<alt_name>
<alt_name_xlate lang="en">HPE Smart Storage Administrator Diagnostic Utility (HPE SSADU) CLI for Linux 64-bit</alt_name_xlate>
</alt_name>
<version value="3.10-3.0" revision="" type_of_change="0"/>
<version value="3.30.14.0" revision="" type_of_change="1"/>
<manufacturer_name>
<manufacturer_name_xlate lang="en">Hewlett Packard Enterprise</manufacturer_name_xlate>
</manufacturer_name>
@ -33,9 +33,9 @@
</operating_systems>
<products>
<product rom="A40"/>
<product rom="U23"/>
<product rom="U37"/>
<product rom="U36"/>
<product rom="U35"/>
<product rom="U34"/>
<product rom="U33"/>
<product rom="U32"/>
@ -52,18 +52,21 @@
<product rom="P95"/>
<product rom="U39"/>
<product rom="O42"/>
<product rom="U44"/>
<product rom="I39"/>
<product rom="I38"/>
<product rom="U25"/>
<product rom="I37"/>
<product rom="I36"/>
<product rom="U24"/>
<product rom="U25"/>
<product rom="U43"/>
<product rom="U40"/>
<product rom="U41"/>
<product rom="U20"/>
<product rom="U21"/>
<product rom="U22"/>
<product rom="U23"/>
<product rom="A41"/>
<product rom="U45"/>
<product rom="Carbondale14"/>
<product rom="U19"/>
<product rom="P89"/>
@ -93,7 +96,7 @@
<languages langlist="fr,en,de,it,ja,es">
<languages_xlate lang="en">French,English (US),German,Italian,Japanese,Spanish</languages_xlate>
</languages>
<release_date year="2017" month="06" day="05" hour="00" minute="00" second="00"/>
<release_date year="2018" month="02" day="22" hour="15" minute="53" second="58"/>
<description>
<description_xlate lang="en"><![CDATA[The HPE Smart Storage Administrator Diagnostic Utility CLI is a commandline-based disk configuration program for Smart Array Controllers and any supported devices, including providing HPE SmartSSD Wear Gauge information for supported drives.]]></description_xlate>
</description>
@ -117,7 +120,7 @@
</installation_notes>
<availability_notes/>
<documentation_notes/>
<upgrade_requirement value="Optional"/>
<upgrade_requirement value="Recommended"/>
<prerequisites>
<supported_operating_systems>
<supported_operating_system platform="suse_linux_enterprise_server_x86_64" major="12" minor="0" sr="OEM" name="SUSE Linux Enterprise Server 12"/>
@ -134,8 +137,8 @@
<command/>
<command_params/>
<reboot_required value="no"/>
<reboot_details value="No">
<reboot_details_xlate lang="en">Reboot is not required after installation for updates to take effect and hardware stability to be maintained</reboot_details_xlate>
<reboot_details value="Optional">
<reboot_details_xlate lang="en">Reboot is optional after installation. Updates will be effective after reboot. Hardware stability will be maintained without reboot</reboot_details_xlate>
</reboot_details>
<per_device_install_time_seconds>0</per_device_install_time_seconds>
</install>
@ -153,13 +156,13 @@
</sw_key>
</sw_keys_and>
</sw_keys>
<filename>ssaducli-3.10-3.0.x86_64.rpm</filename>
<filename>ssaducli-3.30-14.0.x86_64.rpm</filename>
<component_config/>
<files>
<file size="3MB" bytes="3620733" date_modified="2017-05-19T08:39:16" md5sum="" sha1sum="" version="3.10" release="3.0">
<name>ssaducli-3.10-3.0.x86_64.rpm</name>
<file size="3MB" bytes="3823577" date_modified="2018-04-25T10:36:24" md5sum="" sha1sum="" version="3.30" release="14.0">
<name>ssaducli-3.30-14.0.x86_64.rpm</name>
<url id="http://ftp.hp.com"/>
<url id="file://.">file://./packages/ssaducli-3.10-3.0.x86_64.rpm</url>
<url id="file://.">file://./packages/ssaducli-3.30-14.0.x86_64.rpm</url>
<file_list>
<file>./opt/smartstorageadmin/ssaducli</file>
<file>./opt/smartstorageadmin/ssaducli/README.TXT</file>
@ -176,10 +179,10 @@
<file_details/>
<revision_history>
<revision>
<version value="3.10-3.0" revision="" type_of_change="0"/>
<version value="3.30.14.0" revision="" type_of_change="1"/>
<revision_enhancements_xlate lang="en">
<revision_enhancements_xlate_part><![CDATA[<ul style="list-style-type:square">
<li>Initial firmware release for HPE P/E-Class SR Gen10 controllers.</li>
<revision_enhancements_xlate_part><![CDATA[<ul>
<li>Added the ability to enable or disable Drive Write Cache for configured and unconfigured drives</li>
</ul>
]]></revision_enhancements_xlate_part>
</revision_enhancements_xlate>
@ -188,13 +191,15 @@
</revision_fixes_xlate>
</revision>
<revision>
<version value="2.65-7.0" type_of_change="0"/>
<version value="3.25.4.0" type_of_change="0"/>
<revision_enhancements_xlate lang="en">
<revision_enhancements_xlate_part/>
<revision_enhancements_xlate_part><![CDATA[<ul>
<li>Added support for Freeze/Anti-freeze of the Sanitize command.</li>
</ul>
]]></revision_enhancements_xlate_part>
</revision_enhancements_xlate>
<revision_fixes_xlate lang="en">
<revision_fixes_xlate_part><![CDATA[<p>SSA incorrectly displays 64 characters&nbsp;for the encryption master key length in local mode. The length was changed to 32 characters.</p>
]]></revision_fixes_xlate_part>
<revision_fixes_xlate_part/>
</revision_fixes_xlate>
</revision>
</revision_history>